BPG is committed to discovery and dissemination of knowledge
Featured Articles
6/18/2025 9:06:01 AM | Browse: 7 | Download: 47
Publication Name World Journal of Orthopedics
Manuscript ID 107292
Country United States
Received
2025-03-30 04:37
Peer-Review Started
2025-03-30 04:37
To Make the First Decision
Return for Revision
2025-04-03 04:18
Revised
2025-04-17 12:09
Second Decision
2025-05-22 02:42
Accepted by Journal Editor-in-Chief
Accepted by Executive Editor-in-Chief
2025-05-24 02:06
Articles in Press
2025-05-24 02:06
Publication Fee Transferred
Edit the Manuscript by Language Editor
Typeset the Manuscript
2025-06-05 00:34
Publish the Manuscript Online
2025-06-18 08:20
ISSN 2218-5836 (online)
Open Access This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/Licenses/by-nc/4.0/
Copyright © The Author(s) 2025. Published by Baishideng Publishing Group Inc. All rights reserved.
Article Reprints For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
Permissions For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
Publisher Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
Website http://www.wjgnet.com
Category Orthopedics
Manuscript Type Retrospective Study
Article Title Pure high-offset stems can cause an unexpected increase in femoral length in robotic-assisted primary total hip arthroplasty
Manuscript Source Unsolicited Manuscript
All Author List Wei-Shao Tung, Aidin Eslam Pour, Johannes Sieberer, Claire A Donnelley, Steven M Tommasini and Daniel H Wiznia
Funding Agency and Grant Number
Corresponding Author Wei-Shao Tung, Research Fellow, Department of Orthopaedics and Rehabilitation, Yale University, No. 47 College Street, New Haven, CT 06510, United States. weishao.tung@gmail.com
Key Words Three-dimensional modelling; Total hip arthroplasty; Robotic-assisted surgery; Leg length; Anatomical mechanical femoral angle
Core Tip Discrepancies in leg length can result in patient dissatisfaction, complications, or even a need for revision. Surgeons should be aware of this unexpected increase in femoral length when using a pure high-offset stem in robotic-assisted total hip arthroplasty, especially for patients who may benefit from precise restoration of lower extremity biomechanics. With expanding accessibility of computer-navigated and robotic-assisted total hip arthroplasty platforms, any potential sources of postoperative leg length discrepancy should be identified during preoperative templating and necessary alterations to the surgical plan should be made to accommodate this unexpected difference when using a pure high-offset stem.
Publish Date 2025-06-18 08:20
Citation <p>Tung WS, Eslam Pour A, Sieberer J, Donnelley CA, Tommasini SM, Wiznia DH. Pure high-offset stems can cause an unexpected increase in femoral length in robotic-assisted primary total hip arthroplasty. <i>World J Orthop</i> 2025; 16(6): 107292</p>
URL https://www.wjgnet.com/2218-5836/full/v16/i6/107292.htm
DOI https://dx.doi.org/10.5312/wjo.v16.i6.107292
Full Article (PDF) WJO-16-107292-with-cover.pdf
Manuscript File 107292_Auto_Edited_062727.docx
Answering Reviewers 107292-answering-reviewers.pdf
Audio Core Tip 107292-audio.m4a
Biostatistics Review Certificate 107292-biostatistics-statement.pdf
Conflict-of-Interest Disclosure Form 107292-conflict-of-interest-statement.pdf
Copyright License Agreement 107292-copyright-assignment.pdf
Signed Informed Consent Form(s) or Document(s) 107292-informed-consent-statement.pdf
Institutional Review Board Approval Form or Document 107292-institutional-review-board-statement.pdf
Peer-review Report 107292-peer-reviews.pdf
Scientific Misconduct Check 107292-scientific-misconduct-check.png
Scientific Editor Work List 107292-scientific-editor-work-list.pdf
CrossCheck Report 107292-crosscheck-report.pdf