BPG is committed to discovery and dissemination of knowledge
Featured Articles
11/21/2016 10:43:00 AM | Browse: 575 | Download: 1128
 |
Received |
|
2016-04-21 15:35 |
 |
Peer-Review Started |
|
2016-04-22 16:31 |
 |
To Make the First Decision |
|
2016-07-04 15:23 |
 |
Return for Revision |
|
2016-07-05 18:43 |
 |
Revised |
|
2016-08-25 00:00 |
 |
Second Decision |
|
2016-09-12 10:03 |
 |
Accepted by Journal Editor-in-Chief |
|
|
 |
Accepted by Executive Editor-in-Chief |
|
2016-09-22 14:07 |
 |
Articles in Press |
|
2016-09-22 14:07 |
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
|
 |
Typeset the Manuscript |
|
2016-11-16 12:25 |
 |
Publish the Manuscript Online |
|
2016-11-21 08:10 |
ISSN |
1949-8470 (online) |
Open Access |
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
Copyright |
© The Author(s) 2016. Published by Baishideng Publishing Group Inc. All rights reserved. |
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Gastroenterology & Hepatology |
Manuscript Type |
Retrospective Study |
Article Title |
CO2BOLD assessment of moyamoya syndrome: Validation with single photon emission computed tomography and positron emission tomography imaging
|
Manuscript Source |
Invited Manuscript |
All Author List |
Alain Pellaton, Philippe Bijlenga, Laurie Bouchez, Victor Cuvinciuc, Isabelle Barnaure, Valentina Garibotto, Karl-Olof Lövblad and Sven Haller |
Funding Agency and Grant Number |
Funding Agency |
Grant Number |
Swiss National Science Foundation |
140340 |
|
Corresponding Author |
Karl-Olof Lövblad, MD, Diagnostic and Interventional Neuroradiology, Geneva University Hospitals, 4 rue Gabrielle-Perret Gentil, 1211 Geneva, Switzerland. karl-olof.lovblad@hcuge.ch |
Key Words |
Moyamoya; Vascular reserve; CO2BOLD; Cerebrovascular reserve |
Core Tip |
Inter-rater agreement of cerebrovascular reserve (CVR) assessment in CO2BOLD is similar to positron emission tomography (PET)/single photon emission computed tomography (SPECT); CO2BOLD has a sensitivity of 86% and specificity of 43% compared to PET/SPECT; Overall, CO2BOLD tends to over-estimate reduction in CVR compared to PET and SPECT as reference standard; Taking this over-estimation of CO2BOLD into account would further improve its sensitivity and specificity; CVR can be assessed using CO2BOLD for pre-surgical evaluation and follow-up of moyamoya syndrome patients. |
Publish Date |
2016-11-21 08:10 |
Citation |
Pellaton A, Bijlenga P, Bouchez L, Cuvinciuc V, Barnaure I, Garibotto V, Lövblad KO, Haller S. CO2BOLD assessment of moyamoya syndrome: Validation with single photon emission computed tomography and positron emission tomography imaging. World J Radiol 2016; 8(11): 887-894 |
URL |
http://www.wjgnet.com/1949-8470/full/v8/i11/887.htm |
DOI |
http://dx.doi.org/10.4329/wjr.v8.i11.887 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
California Corporate Number: 3537345