BPG is committed to discovery and dissemination of knowledge
Featured Articles
8/17/2023 2:34:05 PM | Browse: 284 | Download: 1000
 |
Received |
|
2023-04-24 12:55 |
 |
Peer-Review Started |
|
2023-04-24 12:57 |
 |
First Decision by Editorial Office Director |
|
2023-06-01 08:15 |
 |
Return for Revision |
|
2023-06-01 08:15 |
 |
Revised |
|
2023-06-26 14:15 |
 |
Publication Fee Transferred |
|
|
 |
Second Decision by Editor |
|
2023-08-01 02:31 |
 |
Second Decision by Editor-in-Chief |
|
|
 |
Final Decision by Editorial Office Director |
|
2023-08-01 08:05 |
 |
Articles in Press |
|
2023-08-01 08:05 |
 |
Edit the Manuscript by Language Editor |
|
2023-07-31 08:19 |
 |
Typeset the Manuscript |
|
2023-08-10 05:26 |
 |
Publish the Manuscript Online |
|
2023-08-17 10:54 |
| ISSN |
2218-5836 (online) |
| Open Access |
This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
| Copyright |
©The Author(s) 2023. Published by Baishideng Publishing Group Inc. All rights reserved. |
| Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
| Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
| Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
| Website |
http://www.wjgnet.com |
| Category |
Orthopedics |
| Manuscript Type |
Case Report |
| Article Title |
Metallosis with spinal implant loosening after spinal instrumentation: A case report
|
| Manuscript Source |
Unsolicited Manuscript |
| All Author List |
Yiu Hin Kwan, Hong Lee Terry Teo, Shree Kumar Dinesh and Wee Lim Loo |
| Funding Agency and Grant Number |
|
| Corresponding Author |
Yiu Hin Kwan, MBBS, Doctor, Doctor, Department of Orthopaedic Surgery, Changi General Hospital, 2 Simei Street 3, Singapore 529889, Singapore. yiuhin@gmail.com |
| Key Words |
Metallosis; Spine; Instrumentation; Implant loosening; Corrosion; Case report |
| Core Tip |
This paper describes a rare case of metallosis after spinal instrumentation and discusses the methods of diagnosing and risk factors contributing to spinal metallosis. A review of the current literature as presented in this paper demonstrates the scarcity of studies on spinal metallosis after spinal instrumentation, despite the fact that a diagnosis of spinal metallosis should be promptly identified and treated by revision surgery. It is also important to understand that the presence of metallosis after spinal instrumentation likely indicates a more complex underlying problem, such as instability of the spinal implants. |
| Publish Date |
2023-08-17 10:54 |
| Citation |
Kwan YH, Teo HLT, Dinesh SK, Loo WL. Metallosis with spinal implant loosening after spinal instrumentation: A case report. World J Orthop 2023; 14(8): 651-661 |
| URL |
https://www.wjgnet.com/2218-5836/full/v14/i8/651.htm |
| DOI |
https://dx.doi.org/10.5312/wjo.v14.i8.651 |
All content on this site: Copyright © 1993-2026 Baishideng Publishing Group Inc, its licensors, and contributors. All rights are reserved, including those for text and data mining, AI training, and similar technologies. For all open access content, the relevant licensing terms apply.