BPG is committed to discovery and dissemination of knowledge
Featured Articles
10/24/2023 7:49:06 AM | Browse: 267 | Download: 694
 |
Received |
|
2023-09-06 13:25 |
 |
Peer-Review Started |
|
2023-09-06 13:27 |
 |
To Make the First Decision |
|
|
 |
Return for Revision |
|
2023-09-19 07:04 |
 |
Revised |
|
2023-09-20 15:53 |
 |
Second Decision |
|
2023-09-28 02:44 |
 |
Accepted by Journal Editor-in-Chief |
|
|
 |
Accepted by Executive Editor-in-Chief |
|
2023-09-28 05:48 |
 |
Articles in Press |
|
2023-09-28 05:48 |
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
|
 |
Typeset the Manuscript |
|
2023-10-23 01:33 |
 |
Publish the Manuscript Online |
|
2023-10-24 07:40 |
ISSN |
1949-8470 (online) |
Open Access |
This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/Licenses/by-nc/4.0/ |
Copyright |
© The Author(s) 2023. Published by Baishideng Publishing Group Inc. All rights reserved. |
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Radiology, Nuclear Medicine & Medical Imaging |
Manuscript Type |
Retrospective Study |
Article Title |
Two-point Dixon and six-point Dixon magnetic resonance techniques in the detection, quantification and grading of hepatic steatosis
|
Manuscript Source |
Unsolicited Manuscript |
All Author List |
Mohamed Elfaal, Alanna Supersad, Craig Ferguson, Stephanie Locas, Florin Manolea, Mitchell P Wilson, Medica Sam, Wendy Tu and Gavin Low |
Funding Agency and Grant Number |
|
Corresponding Author |
Gavin Low, MBChB, MPhil, Professor, Department of Radiology & Diagnostic Imaging, University of Alberta, WMC 2B2.41 8440-112 ST, Edmonton T6G2B7, Alberta, Canada. gavinlow@mic.ca |
Key Words |
Chemical shift encoded Dixon magnetic resonance techniques; Hepatic steatosis; Liver fat quantification; Magnetic resonance spectroscopy; Proton density fat fraction; Ultrasound |
Core Tip |
Fat fraction (FF) estimates on the Dixon techniques (two-point Dixon and six-point Dixon) have excellent correlation with magnetic resonance spectroscopy-proton density FF (MRS-PDFF), and excellent accuracy in detecting steatosis, and grading severe steatosis. However, in iron overload, two-point Dixon was not evaluable due to confounding effect on liver signal from T2* decay. The excellent correlation between the Dixon techniques vs MRS-PDFF was not affected by co-existing liver fibrosis. |
Publish Date |
2023-10-24 07:40 |
Citation |
Elfaal M, Supersad A, Ferguson C, Locas S, Manolea F, Wilson MP, Sam M, Tu W, Low G. Two-point Dixon and six-point Dixon magnetic resonance techniques in the detection, quantification and grading of hepatic steatosis. World J Radiol 2023; 15(10): 293-303 |
URL |
https://www.wjgnet.com/1949-8470/full/v15/i10/293.htm |
DOI |
https://dx.doi.org/10.4329/wjr.v15.i10.293 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
California Corporate Number: 3537345