BPG is committed to discovery and dissemination of knowledge
Featured Articles
7/12/2024 2:19:23 PM | Browse: 178 | Download: 280
 |
Received |
|
2024-01-02 16:55 |
 |
Peer-Review Started |
|
2024-01-02 16:55 |
 |
To Make the First Decision |
|
|
 |
Return for Revision |
|
2024-01-22 05:48 |
 |
Revised |
|
2024-02-11 18:02 |
 |
Second Decision |
|
2024-05-09 02:43 |
 |
Accepted by Journal Editor-in-Chief |
|
|
 |
Accepted by Executive Editor-in-Chief |
|
2024-05-09 05:39 |
 |
Articles in Press |
|
2024-05-09 05:39 |
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
|
 |
Typeset the Manuscript |
|
2024-07-05 05:48 |
 |
Publish the Manuscript Online |
|
2024-07-12 05:36 |
ISSN |
2218-5836 (online) |
Open Access |
This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: https://creativecommons.org/licenses/by-nc/4.0/ |
Copyright |
© The Author(s) 2024. Published by Baishideng Publishing Group Inc. All rights reserved. |
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Orthopedics |
Manuscript Type |
Case Report |
Article Title |
Bone graft incorporation failure with inappropriate limb load transfer can lead to aseptic acetabular loosening of metal-on-metal prosthesis: A case report
|
Manuscript Source |
Unsolicited Manuscript |
All Author List |
Rafał Stanisław Domagalski, Bogdan Dugiełło, Sonia Rokicka, Szymon Czech, Rafał Skowroński, Dominika Rokicka, Marta Patrycja Wróbel, Krzysztof Strojek and Tomasz Stołtny |
Funding Agency and Grant Number |
|
Corresponding Author |
Bogdan Dugiełło, MD, Doctor, Doctor, District Railway Hospital, Medical University of Silesia, Panewnicka Street 65, Katowice 40-760, Poland. bogdan.dugiello@gmail.com |
Key Words |
Acetabular loosening; Limb load; Stress shielding effect; Revision hip arthroplasty; Case report |
Core Tip |
This article explores a rare case of acetabular loosening following total hip arthroplasty (THA) due to improper limb load transfer after hip trauma. A 63-year-old patient underwent THA with a metal-on-metal bearing, initially showing no complications. However, 2 years later, acetabular component loosening occurred, requiring revision THA with a ceramic-on-ceramic bearing. The study emphasizes the impact of limb load distribution on hip arthroplasty outcomes. Post-revision, the patient showed significant improvement in clinical parameters. This case underscores the need for careful consideration of limb load transfer after THA to mitigate risks of loosening. |
Publish Date |
2024-07-12 05:36 |
Citation |
<p>Domagalski RS, Dugiełło B, Rokicka S, Czech S, Skowroński R, Rokicka D, Wróbel MP, Strojek K, Stołtny T. Bone graft incorporation failure with inappropriate limb load transfer can lead to aseptic acetabular loosening of metal-on-metal prosthesis: A case report. <i>World J Orthop</i> 2024; 15(7): 668-674</p> |
URL |
https://www.wjgnet.com/2218-5836/full/v15/i7/668.htm |
DOI |
https://dx.doi.org/10.5312/wjo.v15.i7.668 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
California Corporate Number: 3537345