| ISSN |
1007-9327 (print) and 2219-2840 (online) |
| Open Access |
This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/Licenses/by-nc/4.0/ |
| Copyright |
© The Author(s) 2025. Published by Baishideng Publishing Group Inc. All rights reserved. |
| Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
| Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
| Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
| Website |
http://www.wjgnet.com |
| Category |
Gastroenterology & Hepatology |
| Manuscript Type |
Randomized Controlled Trial |
| Article Title |
Covering the biopsy hole check valve with “enzymolysis gauze” reduces bacterial contamination in the endoscopy room
|
| Manuscript Source |
Unsolicited Manuscript |
| All Author List |
Hu-Bin Xia, Ying-Dong Hou, Yuan Zhang, Ai-Yu Yu, Qi Ding, Wen-Li Ruan, Yi-Shen Mao, Shu-Jiong Feng, Cong Ding and Yi-Feng Zhou |
| ORCID |
|
| Funding Agency and Grant Number |
| Funding Agency |
Grant Number |
| Construction Fund of Key Medical Disciplines of Hangzhou |
2025HZGF05 |
| Key R&D Program of Zhejiang Province |
No. 2023C03054, No. 2024C03048 |
| Key Discipline of lntegrated Chinese and Western Medicine (Digestive Diseases) in Zhejiang Province |
2024-XK-61 |
| Zhejiang Province Medical and Health Science and Technology Plan Project |
2021KY848 |
|
| Corresponding Author |
Yi-Feng Zhou, Chief, MD, Department of Gastroenterology, Affiliated Hangzhou First People's Hospital, School of Medicine, Westlake University, No. 261 Huansha Road, Shangcheng District, Hangzhou 310000, Zhejiang Province, China. zhouyifeng@hospital.westlake.edu.cn |
| Key Words |
Bacterial contamination; Aerosol; Enteric bacterial microflora; Colonoscope; Endoscopy; Enzymolysis gauze; Biopsy hole check valve; Infection |
| Core Tip |
Endoscopy-related infections are underestimated due to difficulties in diagnosis, misdiagnosis, and underreporting. Bacterial contamination during colonoscopy poses a significant challenge, yet limited research has focused on bacterial aerosols, particularly those originating from the biopsy valve. This study introduces a simple yet effective approach to mitigate bacterial aerosol contamination in the endoscopy room. Our findings demonstrate that covering the biopsy valve with an enzymolysis gauze during colonoscopy significantly reduces airborne bacterial aerosols. This could improve safety for both patients and healthcare personnel. |
| Publish Date |
2025-11-28 03:10 |
| Citation |
Xia HB, Hou YD, Zhang Y, Yu AY, Ding Q, Ruan WL, Mao YS, Feng SJ, Ding C, Zhou YF. Covering the biopsy hole check valve with “enzymolysis gauze” reduces bacterial contamination in the endoscopy room. World J Gastroenterol 2025; 31(44): 113650 |
| URL |
https://www.wjgnet.com/1007-9327/full/v31/i44/113650.htm |
| DOI |
https://dx.doi.org/10.3748/wjg.v31.i44.113650 |