BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
1/21/2015 5:04:00 PM | Browse: 1105 | Download: 1755
Publication Name World Journal of Cardiology
Manuscript ID 13315
Country United States
ISSN 1949-8462 (online)
Open Access This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Copyright © The Author(s) 2015. Published by Baishideng Publishing Group Inc. All rights reserved.
Article Reprints For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
Permissions For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
Publisher Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
Website http://www.wjgnet.com
Category Cardiac & Cardiovascular Systems
Manuscript Type Case Report
Article Title Permanent transvenous pacemaker implantation in a patient with Cor triatriatum dextrum
Manuscript Source Invited Manuscript
All Author List Kun Xiang, George V Moukarbel and Blair Grubb
Funding Agency and Grant Number
Corresponding Author Blair Grubb, MD, Division of Cardiovascular Medicine, University of Toledo Medical Center, 3000 Arlington Avenue, Toledo, OH 43614, United States. blair.grubb@utoledo.edu
Key Words Congenital heart defect; Complete heart block; Inter-atrial membrane; Dual-chamber pacemaker
Core Tip Cor triatriatum dextrum is an extremely rare congenital heart abnormality in which the right atrium is separated by a persistent fibrous membrane. This membrane poses a technical challenge for dual-chamber pacemaker placement through the transvenous approach. Here we report the first transvenous pacemaker placement in a patient with cor triatriatum dextrum. A thorough pre-operative evaluation by transesophageal echocardiogram was critical for the planning of transvenous catheter-based right-sided leads placement. Using specially designed pacemaker leads and cautious intra-procedural maneuvering under fluoroscopic guidance ensured procedural success.
Publish Date 2015-01-21 17:04
Citation Xiang K, Moukarbel GV, Grubb B. Permanent transvenous pacemaker implantation in a patient with Cor triatriatum dextrum. World J Cardiol 2015; 7(1): 43-46
URL http://www.wjgnet.com/1949-8462/full/v7/i1/43.htm
DOI http://dx.doi.org/10.4330/wjc.v7.i1.43
Full Article (PDF) WJC-7-43.pdf
Full Article (Word) WJC-7-43.doc