BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
6/3/2015 12:01:00 PM | Browse: 905 | Download: 1339
 |
Received |
|
2014-09-19 17:25 |
 |
Peer-Review Started |
|
2014-09-20 13:34 |
 |
To Make the First Decision |
|
2014-12-17 11:35 |
 |
Return for Revision |
|
2014-12-22 08:59 |
 |
Revised |
|
2015-03-25 00:00 |
 |
Second Decision |
|
2015-04-01 14:52 |
 |
Accepted by Journal Editor-in-Chief |
|
2015-04-01 20:04 |
 |
Accepted by Executive Editor-in-Chief |
|
2015-04-09 16:40 |
 |
Articles in Press |
|
2015-04-09 16:40 |
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
|
 |
Typeset the Manuscript |
|
2015-05-21 15:26 |
 |
Publish the Manuscript Online |
|
2015-06-03 12:00 |
ISSN |
1948-5182 (online) |
Open Access |
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
Copyright |
© The Author(s) 2015. Published by Baishideng Publishing Group Inc. All rights reserved. |
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Gastroenterology & Hepatology |
Manuscript Type |
Review |
Article Title |
Hemodynamic monitoring during liver transplantation: A state of the art review
|
Manuscript Source |
Invited Manuscript |
All Author List |
Mona Rezai Rudnick, Lorenzo De Marchi and Jeffrey S Plotkin |
Funding Agency and Grant Number |
|
Corresponding Author |
Jeffrey S Plotkin, MD, Department of Anesthesiology, Georgetown University Hospital, CCC Building Lower Level Rm CL-60, 3800 Reservoir Road, NW Washington, DC 20007, United States. plotkinj@gunet.georgetown.edu
|
Key Words |
Intraoperative monitoring; Physiologic monitoring; Liver transplantation |
Core Tip |
Accurate hemodynamic monitoring is essential to safely navigate orthotopic liver transplantation. Although specific indications for pulmonary artery catheters exist, their use has slowly been replaced by newer technologies which offer less invasive and more accurate measurement. The latest evidence on the strengths and limitations of arterial pulse wave form analysis, intraoperative transesophageal echo-cardiography, peripheral vs central arterial blood pressure monitoring and pulmonary arterial catheters are discussed.
|
Publish Date |
2015-06-03 12:00 |
Citation |
Rudnick MR, De Marchi L, Plotkin JS. Hemodynamic monitoring during liver transplantation: A state of the art review. World J Hepatol 2015; 7(10): 1302-1311 |
URL |
http://www.wjgnet.com/1948-5182/full/v7/i10/1302.htm |
DOI |
http://dx.doi.org/10.4254/wjh.v7.i10.1302 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
California Corporate Number: 3537345