BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
6/11/2015 10:11:00 AM | Browse: 1401 | Download: 2124
Publication Name World Journal of Gastroenterology
Manuscript ID 15053
Country China
ISSN 1007-9327 (print) and 2219-2840 (online)
Open Access This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Copyright © The Author(s) 2015. Published by Baishideng Publishing Group Inc. All rights reserved.
Article Reprints For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
Permissions For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
Publisher Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
Website http://www.wjgnet.com
Category Infectious Diseases
Manuscript Type Prospective Study
Article Title 3.0T 1H magnetic resonance spectroscopy for assessment of steatosis in patients with chronic hepatitis C
Manuscript Source Unsolicited Manuscript
All Author List Qian Zhang, Hui-Mao Zhang, Wen-Qian Qi, Yong-Gui Zhang, Ping Zhao, Jian Jiao, Jiang-Bin Wang and Chun-Yu Zhang
Funding Agency and Grant Number
Funding Agency Grant Number
National Natural Science Foundation of China 30970415
Corresponding Author Dr. Chun-Yu Zhang, Department of Radiology, 1st Hospital Affiliated to Jilin University, 71 Xinmin street, Changchun 130000, Jilin Province, China. zhangchunyu@163.com
Key Words 1H; Magnetic resonance spectroscopy; Hepatitis C; Antiviral therapy
Core Tip The aim of this study was to investigate the utility of 1H magnetic resonance imaging spectroscopy (1H MRS) as a noninvasive test of steatosis in patients infected with hepatitis C virus. Ninety chronic hepatitis C patients with pathology data underwent 3.0T 1H MRS. 1H MRS is a noninvasive technique that can be used to provide liver steatosis information on hepatic metabolic processes. This study indicates that the 1H MRS can be used as an indicator of steatosis in chronic hepatitis C patients.
Publish Date 2015-06-11 10:11
Citation Zhang Q, Zhang HM, Qi WQ, Zhang YG, Zhao P, Jiao J, Wang JB, Zhang CY. 3.0T 1H magnetic resonance spectroscopy for assessment of steatosis in patients with chronic hepatitis C. World J Gastroenterol 2015; 21(21): 6736-6744
URL http://www.wjgnet.com/1007-9327/full/v21/i21/6736.htm
DOI http://dx.doi.org/10.3748/wjg.v21.i21.6736
Full Article (PDF) WJG-21-6736.pdf
Full Article (Word) WJG-21-6736.doc