BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
9/11/2014 2:08:00 PM | Browse: 682 | Download: 979
 |
Received |
|
2012-12-23 03:06 |
 |
Peer-Review Started |
|
2012-12-24 15:09 |
 |
To Make the First Decision |
|
2013-03-18 15:22 |
 |
Return for Revision |
|
2013-03-20 10:25 |
 |
Revised |
|
2013-04-01 21:19 |
 |
Second Decision |
|
2013-05-17 16:26 |
 |
Accepted by Journal Editor-in-Chief |
|
2013-05-17 22:07 |
 |
Accepted by Executive Editor-in-Chief |
|
2013-05-19 23:22 |
 |
Articles in Press |
|
|
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
2013-05-24 00:57 |
 |
Typeset the Manuscript |
|
2013-06-09 11:05 |
 |
Publish the Manuscript Online |
|
2013-07-16 22:58 |
Category |
Obstetrics & Gynecology |
Manuscript Type |
Minireviews |
Article Title |
Intrapartum application of the continuous glucose monitoring system in pregnancies complicated with diabetes: A review and feasibility study
|
Manuscript Source |
Invited Manuscript |
All Author List |
Vicentia C Harizopoulou, Panagiotis Tsiartas, Dimitrios G Goulis, Dimitrios Vavilis, Grigorios Grimbizis, Theodoros D Theodoridis and Basil C Tarlatzis |
Funding Agency and Grant Number |
|
Corresponding Author |
Vicentia C Harizopoulou, Midwife, MSc, PhDc, Unit for Human Reproduction, First Department of Obstetrics and Gynaecology, Papageorgiou General Hospital, Ring Road, Nea Efkarpia, 54603 Thessaloniki, Greece. vikentiaha@yahoo.com
|
Key Words |
Diabetes mellitus; Pregnancy; Intrapartum management; Glucose monitoring protocols; Continuous glucose monitoring system |
Core Tip |
In pregnancies complicated with diabetes, intrapartum maternal normoglycemia seems to play an important role in the prevention of adverse perinatal outcomes. Several glucose monitoring protocols have been developed, aiming to achieve a tight glucose monitoring and control intrapartum. The continuous glucose monitoring system is a relatively new technology; its intrapartum application in pregnancies complicated with diabetes is feasible, allows for a closer observation of glucose concentrations and is expected to lead to a more etiological management of both the mother and her fetus/infant.
|
Publish Date |
2013-07-16 22:58 |
Citation |
Harizopoulou VC, Tsiartas P, Goulis DG, Vavilis D, Grimbizis G, Theodoridis TD, Tarlatzis BC. Intrapartum application of the continuous glucose monitoring system in pregnancies complicated with diabetes: A review and feasibility study. World J Obstet Gynecol 2013; 2(3): 42-46 |
URL |
http://www.wjgnet.com/2218-6220/full/v2/i3/42.htm |
DOI |
http://dx.doi.org/10.5317/wjog.v2.i3.42 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
California Corporate Number: 3537345