ISSN |
1949-8462 (online) |
Open Access |
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
Copyright |
© The Author(s) 2015. Published by Baishideng Publishing Group Inc. All rights reserved. |
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Cardiac & Cardiovascular Systems |
Manuscript Type |
Retrospective Cohort Study |
Article Title |
Right ventricular septal pacing: Safety and efficacy in a long term follow up
|
Manuscript Source |
Invited Manuscript |
All Author List |
Eraldo Occhetta, Gianluca Quirino, Lara Baduena, Rosaria Nappo, Chiara Cavallino, Emanuela Facchini, Paolo Pistelli, Andrea Magnani, Miriam Bortnik, Gabriella Francalacci, Gabriele Dell’Era, Laura Plebani and Paolo Marino |
Funding Agency and Grant Number |
|
Corresponding Author |
Dr. Eraldo Occhetta, Cardiology Department, AOU Maggiore della Carità, Corso Mazzini 18, 28100 Novara, Italy. eraldo.occhetta@maggioreosp.novara.it
|
Key Words |
Right ventricular septal pacing; Parahisian pacing; Resynchronization therapy; Left ventricular cardiac function; Permanent cardiac pacing |
Core Tip |
We evaluated the safety and efficacy of the permanent high interventricular septal pacing in a long term follow up, as alternative to right ventricular apical pacing. We retrospective evaluated 244 patients with a narrow QRS implanted with a single/dual chamber pacemaker with ventricular screw-in lead placed at the right ventricular high septal (parahisian) site. Contemporary we checked the clinical evolution of two control groups of patients: without ventricular stimu-lation and with conventional right ventricular apical stimulation. In a long term follow up we observed stability of pacing parameters and ejection fraction, and improvement in New York Heart Association class, quality of life and exercise tolerance.
|
Publish Date |
2015-08-27 11:20 |
Citation |
Occhetta E, Quirino G, Baduena L, Nappo R, Cavallino C, Facchini E, Pistelli P, Magnani A, Bortnik M, Francalacci G, Dell'Era G, Plebani L, Marino P. Right ventricular septal pacing: Safety and efficacy in a long term follow up. World J Cardiol 2015; 7(8): 490-498 |
URL |
http://www.wjgnet.com/1949-8462/full/v7/i8/490.htm |
DOI |
http://dx.doi.org/10.4330/wjc.v7.i8.490 |