BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
12/2/2015 11:21:00 AM | Browse: 1010 | Download: 1988
 |
Received |
|
2015-02-09 08:29 |
 |
Peer-Review Started |
|
2015-02-09 16:46 |
 |
To Make the First Decision |
|
2015-06-03 14:39 |
 |
Return for Revision |
|
2015-06-04 16:16 |
 |
Revised |
|
2015-06-26 13:19 |
 |
Second Decision |
|
2015-09-28 14:38 |
 |
Accepted by Journal Editor-in-Chief |
|
|
 |
Accepted by Executive Editor-in-Chief |
|
2015-10-13 17:41 |
 |
Articles in Press |
|
2015-10-13 17:41 |
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
|
 |
Typeset the Manuscript |
|
2015-11-11 17:36 |
 |
Publish the Manuscript Online |
|
2015-11-30 08:10 |
ISSN |
1949-8462 (online) |
Open Access |
Open-Access: This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
|
Copyright |
© The Author(s) 2015. Published by Baishideng Publishing Group Inc. All rights reserved.
|
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Cardiac & Cardiovascular Systems |
Manuscript Type |
Prospective Study |
Article Title |
Comparison of echocardiography and device based algorithm for atrio-ventricular delay optimization in heart block patients
|
Manuscript Source |
Unsolicited Manuscript |
All Author List |
Rajesh Vijayvergiya and Ankur Gupta |
Funding Agency and Grant Number |
|
Corresponding Author |
Dr. Rajesh Vijayvergiya, MD, DM, FSCAI, FISES, FACC, Profesor, Department of Cardiology, Advanced Cardiac Centre, Post Graduate Institute of Medical Education and Research, Sector 12, Chandigarh 160012,
India. rajeshvijay999@hotmail.com
|
Key Words |
Atrio-ventricular delay optimization; Complete heart block; Doppler echocardiography; Dual chamber pacemaker; Hemodynamics; QuickOpt algorithm |
Core Tip |
Optimization of sensed and paced atrio-ventricular (AV/PV) delay is required for better hemodynamics in patients with complete heart block (CHB). Aim of the present study was to compare the AV/PV delay optimization by echocardiography and intra-cardiac electrocardiogram (IEGM) based QuickOpt algorithm in patients with CHB. We prospectively enrolled 20 patients of CHB who were implanted with a dual chamber pacemaker. A velocity time-integral of left ventricular outflow tract was measured following AV/PV delay optimization by both echocardiography and QuickOpt algorithm method. An agreement between the two techniques was assessed by Bland-Altman analysis. Optimal AV and PV delay as assessed by echocardiography was 155.5 ± 14.68 ms and 122.5 ± 17.73 ms (P < 0.0001), respectively and by QuickOpt method was 167.5 ± 16.73 ms and 117.5 ± 9.10 ms (P < 0.0001), respectively. The time required for AV/PV optimization was 45.26 ± 1.73 min by echocardiography and 0.44 ± 0.08 min by QuickOpt method (P < 0.0001). In conclusion, automated programmer based IEGM method is a quick, easy and reliable alternative to echocardiography for optimization of AV/PV delay in CHB patients.
|
Publish Date |
2015-11-30 08:10 |
Citation |
Vijayvergiya R, Gupta A. Comparison of echocardiography and device based algorithm for atrio-ventricular delay optimization in heart block patients. World J Cardiol 2015; 7(11): 801-807 |
URL |
http://www.wjgnet.com/1949-8462/full/v7/i11/801.htm |
DOI |
http://dx.doi.org/10.4330/wjc.v7.i11.801 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
California Corporate Number: 3537345