BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
11/3/2015 8:26:00 AM | Browse: 767 | Download: 1014
 |
Received |
|
2015-02-21 20:28 |
 |
Peer-Review Started |
|
2015-02-22 18:53 |
 |
To Make the First Decision |
|
2015-04-10 17:49 |
 |
Return for Revision |
|
2015-04-17 08:32 |
 |
Revised |
|
2015-06-07 18:00 |
 |
Second Decision |
|
2015-07-06 08:36 |
 |
Accepted by Journal Editor-in-Chief |
|
2015-07-06 14:19 |
 |
Accepted by Executive Editor-in-Chief |
|
2015-07-17 14:29 |
 |
Articles in Press |
|
2015-07-17 14:29 |
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
|
 |
Typeset the Manuscript |
|
2015-10-12 16:31 |
 |
Publish the Manuscript Online |
|
2015-11-03 08:25 |
ISSN |
1949-8462 (online) |
Open Access |
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
Copyright |
© The Author(s) 2015. Published by Baishideng Publishing Group Inc. All rights reserved. |
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Cardiac & Cardiovascular Systems |
Manuscript Type |
Case Report |
Article Title |
Intra-His bundle block in 2:1 atrioventricular block
|
Manuscript Source |
Unsolicited Manuscript |
All Author List |
Seung Pyo Hong, Yon Woong Park and Young Soo Lee |
Funding Agency and Grant Number |
|
Corresponding Author |
Young Soo Lee, MD, Division of Cardiology, Department of Internal Medicine, Daegu Catholic University Medical Center, 33 Duryugongwon-ro 17-gil, Nam-gu, Daegu 705-718, South Korea. mdleeys@cu.ac.kr |
Key Words |
Cardiac electrophysiologic techniques; Bundle of His; Atrioventricular block |
Core Tip |
Intra-hisian atrioventricular (AV) block associated with 2:1 AV block is an uncommon phenomenon, but it is important for the development of complete AV block. We observed a 77-year-old female with 2:1 AV block due to an intra-hisian block. An alternating pattern of the AH conduction was noted on the His-electrogram. The cause of that confusing finding might have been the instability of the catheter for recording the His potential. We could detect a splitting of the His-electrogram with intra-hisian block after minimal manipulation of the catheter. The authors’ observations suggest that catheter stability is important for a precise recording. |
Publish Date |
2015-11-03 08:25 |
Citation |
Hong SP, Park YW, Lee YS. Intra-His bundle block in 2:1 atrioventricular block. World J Cardiol 2015; 7(10): 700-702 |
URL |
http://www.wjgnet.com/1949-8462/full/v7/i10/700.htm |
DOI |
http://dx.doi.org/10.4330/wjc.v7.i10.700 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
California Corporate Number: 3537345