BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
8/28/2015 5:05:00 PM | Browse: 1068 | Download: 2361
 |
Received |
|
2015-03-15 12:03 |
 |
Peer-Review Started |
|
2015-03-15 12:17 |
 |
First Decision by Editorial Office Director |
|
|
 |
Return for Revision |
|
2015-04-15 17:56 |
 |
Revised |
|
2015-05-28 21:25 |
 |
Publication Fee Transferred |
|
|
 |
Second Decision by Editor |
|
2015-06-23 18:27 |
 |
Second Decision by Editor-in-Chief |
|
2015-06-24 01:55 |
 |
Final Decision by Editorial Office Director |
|
2015-06-26 15:10 |
 |
Articles in Press |
|
2015-06-26 15:10 |
 |
Edit the Manuscript by Language Editor |
|
2015-07-29 21:58 |
 |
Typeset the Manuscript |
|
2015-08-14 16:56 |
 |
Publish the Manuscript Online |
|
2015-08-28 17:04 |
| ISSN |
1007-9327 (print) and 2219-2840 (online) |
| Open Access |
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
| Copyright |
© The Author(s) 2015. Published by Baishideng Publishing Group Inc. All rights reserved.
|
| Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
| Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
| Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
| Website |
http://www.wjgnet.com |
| Category |
Gastroenterology & Hepatology |
| Manuscript Type |
Prospective Study |
| Article Title |
Liver reserve function assessment by acoustic radiation force impulse imaging
|
| Manuscript Source |
Unsolicited Manuscript |
| All Author List |
Xiao-Lan Sun, Li-Wei Liang, Hui Cao, Qiong Men, Ke-Zhu Hou, Zhen Chen and Ya-E Zhao |
| Funding Agency and Grant Number |
|
| Corresponding Author |
Li-Wei Liang, BE, Department of Gastroenterology, Shanghai Shidong Hospital, No. 999, Shi Guang Road, Shanghai 200438, China. 1533516615@qq.com |
| Key Words |
Acoustic radiation force impulse; Liver reserve function; Liver tumor; Receiver-operator characteristic |
| Core Tip |
Seventy-six patients with liver tumors were assessed by acoustic radiation force impulse (ARFI) imaging. We found that liver stiffness (LS) was posi-tively correlated with Indocyanine green (ICG)-R15 and the Child-Pugh score, but was negatively correlated with ICG-K. Aspartate aminotransferase, aminotransferase and total bilirubin were positively correlated with LS, while albumin was negatively correlated with LS. The receiver-operator characteristic curve revealed that when LS value was 2.34 m/s, the Youden index was at its highest point. For patients with liver tumors, ARFI imaging is a useful tool to assess liver reserve function. |
| Publish Date |
2015-08-28 17:04 |
| Citation |
Sun XL, Liang LW, Cao H, Men Q, Hou KZ, Chen Z, Zhao YE. Liver reserve function assessment by acoustic radiation force impulse imaging. World J Gastroenterol 2015; 21(32): 9648-9655 |
| URL |
http://www.wjgnet.com/1007-9327/full/v21/i32/9648.htm |
| DOI |
http://dx.doi.org/10.3748/wjg.v21.i32.9648 |
All content on this site: Copyright © 1993-2026 Baishideng Publishing Group Inc, its licensors, and contributors. All rights are reserved, including those for text and data mining, AI training, and similar technologies. For all open access content, the relevant licensing terms apply.