BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
9/14/2015 4:53:00 PM | Browse: 734 | Download: 1241
 |
Received |
|
2015-03-25 08:43 |
 |
Peer-Review Started |
|
2015-03-27 09:11 |
 |
To Make the First Decision |
|
2015-05-18 12:39 |
 |
Return for Revision |
|
2015-05-19 17:32 |
 |
Revised |
|
2015-06-02 01:13 |
 |
Second Decision |
|
2015-06-10 09:20 |
 |
Accepted by Journal Editor-in-Chief |
|
2015-06-10 12:18 |
 |
Accepted by Executive Editor-in-Chief |
|
2015-06-26 15:05 |
 |
Articles in Press |
|
2015-06-26 15:05 |
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
2015-07-21 10:18 |
 |
Typeset the Manuscript |
|
2015-08-13 11:25 |
 |
Publish the Manuscript Online |
|
2015-09-14 16:54 |
ISSN |
1007-9327 (print) and 2219-2840 (online) |
Open Access |
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
Copyright |
© The Author(s) 2015. Published by Baishideng Publishing Group Inc. All rights reserved. |
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Radiology, Nuclear Medicine & Medical Imaging |
Manuscript Type |
Retrospective Study |
Article Title |
Detection of gallbladder stones by dual-energy spectral computed tomography imaging
|
Manuscript Source |
Unsolicited Manuscript |
All Author List |
An-Liang Chen, Ai-Lian Liu, Sheng Wang, Jing-Hong Liu, Ye Ju, Mei-Yu Sun and Yi-Jun Liu |
Funding Agency and Grant Number |
|
Corresponding Author |
Ai-Lian Liu, PhD, Department of Radiology, The First Affiliated Hospital of Dalian Medical University, No. 222 Zhongshan Road, Dalian 116011, Liaoning Province, China. cjr.liuailian@vip.163.com |
Key Words |
Gallbladder stone; Computed tomography; Spectral imaging |
Core Tip |
In traditional computed tomography (CT), gallbladder stones are indicated directly by high-density or low-density stones and indirectly by dilation of the intrahepatic biliary duct, left and right hepatic ducts, biliary duct and gallbladder. However, it is difficult to diagnose iso-density gallbladder stones, because gallbladder stones and bile are difficultly distinguished by traditional CT due to a same density. The development of spectral imaging recoups the defects of traditional CT in the diagnosis of iso-density stones. In spectral imaging, base substance images and low keV images are both promising to improve the detection rate of gallbladder stones; they provide a new approach for the differential diagnosis of gallbladder stones, and the reliable information for the clinical treatment of gallbladder stones. |
Publish Date |
2015-09-14 16:54 |
Citation |
Chen AL, Liu AL, Wang S, Liu JH, Ju Y, Sun MY, Liu YJ. Detection of gallbladder stones by dual-energy spectral computed tomography imaging. World J Gastroenterol 2015; 21(34): 9993-9998 |
URL |
http://www.wjgnet.com/1007-9327/full/v21/i34/9993.htm |
DOI |
http://dx.doi.org/10.3748/wjg.v21.i34.9993 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
California Corporate Number: 3537345