BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
10/16/2015 5:32:00 PM | Browse: 791 | Download: 1704
 |
Received |
|
2015-04-07 08:43 |
 |
Peer-Review Started |
|
2015-04-08 08:28 |
 |
To Make the First Decision |
|
2015-06-03 14:39 |
 |
Return for Revision |
|
2015-06-04 16:59 |
 |
Revised |
|
2015-06-16 16:34 |
 |
Second Decision |
|
2015-08-03 15:01 |
 |
Accepted by Journal Editor-in-Chief |
|
|
 |
Accepted by Executive Editor-in-Chief |
|
2015-08-11 15:15 |
 |
Articles in Press |
|
2015-08-11 15:15 |
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
|
 |
Typeset the Manuscript |
|
2015-10-08 12:04 |
 |
Publish the Manuscript Online |
|
2015-10-16 17:33 |
ISSN |
2307-8960 (online) |
Open Access |
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
Copyright |
© The Author(s) 2015. Published by Baishideng Publishing Group Inc. All rights reserved. |
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Gastroenterology & Hepatology |
Manuscript Type |
Prospective Study |
Article Title |
New tapered metallic stent for unresectable malignant hilar bile duct obstruction
|
Manuscript Source |
Unsolicited Manuscript |
All Author List |
Yuji Sakai, Toshio Tsuyuguchi, Takao Nishikawa, Harutoshi Sugiyama, Reina Sasaki, Dai Sakamoto, Yuto Watanabe, Masato Nakamura, Shin Yasui, Rintaro Mikata and Osamu Yokosuka |
Funding Agency and Grant Number |
|
Corresponding Author |
Yuji Sakai, MD, Department of Gastroenterology and Nephrology, Graduate School of Medicine, Chiba University, Inohana 1-8-1, Chuou-ku, Chiba City 260-8670, Japan. sakai4754@yahoo.co.jp |
Key Words |
Malignant hilar bile duct obstruction; Metallic stent; Tapered metallic stent |
Core Tip |
Placement of a tapered metallic stent in patients with unresectable malignant hilar bile duct obstruction proved useful because it allowed a longer patency period without procedural accidents. |
Publish Date |
2015-10-16 17:33 |
Citation |
Sakai Y, Tsuyuguchi T, Nishikawa T, Sugiyama H, Sasaki R, Sakamoto D, Watanabe Y, Nakamura M, Yasui S, Mikata R, Yokosuka O. New tapered metallic stent for unresectable malignant hilar bile duct obstruction. World J Clin Cases 2015; 3(10): 887-893 |
URL |
http://www.wjgnet.com/2307-8960/full/v3/i10/887.htm |
DOI |
http://dx.doi.org/10.12998/wjcc.v3.i10.887 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
California Corporate Number: 3537345