BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
1/26/2016 5:36:00 PM | Browse: 759 | Download: 1548
 |
Received |
|
2015-04-30 13:32 |
 |
Peer-Review Started |
|
2015-04-30 21:08 |
 |
First Decision by Editorial Office Director |
|
|
 |
Return for Revision |
|
2015-10-28 13:33 |
 |
Revised |
|
2015-11-05 23:20 |
 |
Publication Fee Transferred |
|
|
 |
Second Decision by Editor |
|
2015-11-23 17:56 |
 |
Second Decision by Editor-in-Chief |
|
2015-11-23 21:37 |
 |
Final Decision by Editorial Office Director |
|
2015-12-04 16:07 |
 |
Articles in Press |
|
2015-12-04 16:07 |
 |
Edit the Manuscript by Language Editor |
|
|
 |
Typeset the Manuscript |
|
2016-01-15 16:29 |
 |
Publish the Manuscript Online |
|
2016-01-26 17:37 |
| ISSN |
1949-8470 (online) |
| Open Access |
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
|
| Copyright |
© The Author(s) 2016. Published by Baishideng Publishing Group Inc. All rights reserved. |
| Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
| Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
| Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
| Website |
http://www.wjgnet.com |
| Category |
Oncology |
| Manuscript Type |
Basic Study |
| Article Title |
Leakage-Penumbra effect in intensity modulated radiation therapy step-and-shoot dose delivery
|
| Manuscript Source |
Invited Manuscript |
| All Author List |
Grigor N Grigorov and James CL Chow |
| Funding Agency and Grant Number |
|
| Corresponding Author |
James CL Chow, PhD, Radiation Medicine Program, Princess Margaret Cancer Center, 610 University Avenue, Toronto, ON M5G 2M9,
Canada. james.chow@rmp.uhn.on.ca
|
| Key Words |
Multileaf collimator leakage; Overshoot effect; Beam penumbra; Prostate intensity modulated radiation therapy planning |
| Core Tip |
This manuscript contains discussion of the effect of inter-leaf leakage in multileaf collimator (MLC)-based step-and-shoot intensity-modulated radiotherapy (IMRT) of cancer, and presents a method to measure and correct for this effect. Based on our experience, and as illustrated with a single IMRT plan, we recommend adjusting the width of treatment field for different segments delivered in the step-and-shoot fashion (to reduce overlap effects), and possibly, to include leakage as optimization parameter in treatment planning. In this study, we introduced a novel empirical model for determining the 2-dimensional distribution of dose resulting from transmission through the MLC.
|
| Publish Date |
2016-01-26 17:37 |
| Citation |
Grigorov GN, Chow JCL. Leakage-Penumbra effect in intensity modulated radiation therapy step-and-shoot dose delivery. World J Radiol 2016; 8(1): 73-81 |
| URL |
http://www.wjgnet.com/1949-8470/full/v8/i1/73.htm |
| DOI |
http://dx.doi.org/10.4329/wjr.v8.i1.73 |
All content on this site: Copyright © 1993-2026 Baishideng Publishing Group Inc, its licensors, and contributors. All rights are reserved, including those for text and data mining, AI training, and similar technologies. For all open access content, the relevant licensing terms apply.