BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
2/16/2016 12:14:00 PM | Browse: 1029 | Download: 1373
 |
Received |
|
2015-05-15 09:31 |
 |
Peer-Review Started |
|
2015-05-15 17:23 |
 |
To Make the First Decision |
|
2015-09-28 12:20 |
 |
Return for Revision |
|
2015-09-29 08:44 |
 |
Revised |
|
2015-10-22 02:55 |
 |
Second Decision |
|
2015-11-23 09:15 |
 |
Accepted by Journal Editor-in-Chief |
|
|
 |
Accepted by Executive Editor-in-Chief |
|
2015-12-04 16:34 |
 |
Articles in Press |
|
2015-12-04 16:34 |
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
|
 |
Typeset the Manuscript |
|
2016-01-27 16:20 |
 |
Publish the Manuscript Online |
|
2016-02-16 12:14 |
ISSN |
2218-5836 (online) |
Open Access |
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
|
Copyright |
© The Author(s) 2016. Published by Baishideng Publishing Group Inc. All rights reserved.
|
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Orthopedics |
Manuscript Type |
Basic Study |
Article Title |
Effect of elbow position on radiographic measurements of radio-capitellar alignment
|
Manuscript Source |
Invited Manuscript |
All Author List |
Emilie Sandman, Fanny Canet, Yvan Petit, G-Yves Laflamme, George S Athwal and Dominique M Rouleau |
Funding Agency and Grant Number |
Funding Agency |
Grant Number |
Fondation de Recherche et d’Éducation en Orthopédie de Montréal |
|
|
Corresponding Author |
Dominique M Rouleau, MD, MSc, FRCSC, Hôpital du Sacré-Cœur de Montréal, 5400 Boul Gouin O, Montreal, Quebec H4J 1C5,
Canada. dominique.rouleau@umontreal.ca
|
Key Words |
Elbow subluxation; Radiocapitellar ratio; Elbow; Elbow dislocation |
Core Tip |
Assessing radial head alignment after injury and obtaining perfect lateral radiographs with the elbow at 90° and the forearm in neutral may be difficult. Therefore we designed this study to assess whether the radiocapitellar ratios (RCR) calculated from true lateral radiographs at different positions of elbow flexion and forearm pronosupination differ from those taken in 90° flexion and neutral position. The paper shows that the RCR measurement continues to be an overall valid and reliable method throughout different elbow and forearm positions. However, values in the negative range, > 5% regardless of forearm rotation, should raise suspicion for elbow instability.
|
Publish Date |
2016-02-16 12:14 |
Citation |
Sandman E, Canet F, Petit Y, Laflamme GY, Athwal GS, Rouleau DM. Effect of elbow position on radiographic measurements of radio-capitellar alignment. World J Orthop 2016; 7(2): 117-122 |
URL |
http://www.wjgnet.com/2218-5836/full/v7/i2/117.htm |
DOI |
http://dx.doi.org/10.5312/wjo.v7.i2.117 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
California Corporate Number: 3537345