BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
12/2/2015 11:21:00 AM | Browse: 721 | Download: 1139
 |
Received |
|
2015-05-27 10:45 |
 |
Peer-Review Started |
|
2015-05-28 15:36 |
 |
To Make the First Decision |
|
2015-07-03 16:47 |
 |
Return for Revision |
|
2015-07-10 17:26 |
 |
Revised |
|
2015-07-24 03:44 |
 |
Second Decision |
|
2015-09-10 08:19 |
 |
Accepted by Journal Editor-in-Chief |
|
2015-09-12 03:40 |
 |
Accepted by Executive Editor-in-Chief |
|
2015-09-18 14:10 |
 |
Articles in Press |
|
2015-09-18 14:10 |
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
|
 |
Typeset the Manuscript |
|
2015-11-11 17:41 |
 |
Publish the Manuscript Online |
|
2015-11-30 08:10 |
ISSN |
1949-8462 (online) |
Open Access |
Open-Access: This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
|
Copyright |
© The Author(s) 2015. Published by Baishideng Publishing Group Inc. All rights reserved.
|
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Cardiac & Cardiovascular Systems |
Manuscript Type |
Letter to the Editor |
Article Title |
Imaging of pannus formation in patients with mechanical heart valves
|
Manuscript Source |
Unsolicited Manuscript |
All Author List |
Sabahattin Gündüz, Mehmet Özkan and Mahmut Yesin |
Funding Agency and Grant Number |
|
Corresponding Author |
Sabahattin Gündüz, MD, Cardiologist, Department of Cardiology, Kosuyolu Kartal Heart Training and Research Hospital, Denizer Cad. No: 2, Cevizli kavşağı, 34846 İstanbul, Turkey. sabahattingunduz@yahoo.com
|
Key Words |
Multidetector computed tomography; Pannus formation; Patient prosthesis mismatch; Prosthetic heart valves; Transesophageal echocardiography |
Core Tip |
Elevated transprosthetic gradients may be caused by pannus and/or thrombus formation or patient prosthesis mismatch (PPM). The differentiation between these three diagnoses is essential since the treatment strategy may differ in either etiology. Our report emphasizes the usefulness of cardiac multidetector computerized tomography in cases with suspected pannus formation which may not be diagnosed without surgical confirmation. Moreover, we underline the importance of recognizing PPM which may easily be overlooked in patients with elevated transprosthetic gradients. Indeed, pannus, trombus or any other masses as the cause of prosthetic dysfunction should be ruled out for a diagnosis of PPM.
|
Publish Date |
2015-11-30 08:10 |
Citation |
Gündüz S, Özkan M, Yesin M. Imaging of pannus formation in patients with mechanical heart valves. World J Cardiol 2015; 7(11): 822-823 |
URL |
http://www.wjgnet.com/1949-8462/full/v7/i11/822.htm |
DOI |
http://dx.doi.org/10.4330/wjc.v7.i11.822 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
California Corporate Number: 3537345