BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
12/28/2015 8:56:00 AM | Browse: 1221 | Download: 2278
 |
Received |
|
2015-06-14 18:22 |
 |
Peer-Review Started |
|
2015-06-15 10:50 |
 |
To Make the First Decision |
|
2015-10-21 08:59 |
 |
Return for Revision |
|
2015-10-29 09:52 |
 |
Revised |
|
2015-11-11 21:39 |
 |
Second Decision |
|
2015-12-02 13:51 |
 |
Accepted by Journal Editor-in-Chief |
|
|
 |
Accepted by Executive Editor-in-Chief |
|
2015-12-11 16:54 |
 |
Articles in Press |
|
2015-12-11 16:55 |
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
|
 |
Typeset the Manuscript |
|
2015-12-22 21:14 |
 |
Publish the Manuscript Online |
|
2015-12-28 08:56 |
ISSN |
1949-8470 (online) |
Open Access |
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
|
Copyright |
© The Author(s) 2015. Published by Baishideng Publishing Group Inc. All rights reserved.
|
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Radiology, Nuclear Medicine & Medical Imaging |
Manuscript Type |
Retrospective Study |
Article Title |
Common bile duct diameter in an asymptomatic population: A magnetic resonance imaging study
|
Manuscript Source |
Unsolicited Manuscript |
All Author List |
Rong Peng, Ling Zhang, Xiao-Ming Zhang, Tian-Wu Chen, Lin Yang, Xiao-Hua Huang and Ze-Ming Zhang |
Funding Agency and Grant Number |
|
Corresponding Author |
Xiao-Ming Zhang, MD, PhD, Sichuan Key Laboratory of Medical Imaging, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Wenhua Road 63, Nanchong 637000, Sichuan Province,
China. cjr.zhxm@vip.163.com
|
Key Words |
Adult; Biliary tract; Common bile duct; Magnetic resonance imaging |
Core Tip |
We measured the common bile duct (CBD) diameter by magnetic resonance cholangiopan-creatography (MRCP) for a large asymptomatic popu-lation and suggested the normal upper limit of the duct be set at 6 mm on MRCP. The CBD diameter was correlated with age, and gradually dilates 0.033 mm per year. Respiration didn’t effect on the non-dilated CBD diameter on MRCP. The significant changes of CBD diameter between inspiration and expiration may suggest a dilation of CBD.
|
Publish Date |
2015-12-28 08:56 |
Citation |
Peng R, Zhang L, Zhang XM, Chen TW, Yang L, Huang XH, Zhang ZM. Common bile duct diameter in an asymptomatic population: A magnetic resonance imaging study. World J Radiol 2015; 7(12): 501-508 |
URL |
http://www.wjgnet.com/1949-8470/full/v7/i12/501.htm |
DOI |
http://dx.doi.org/10.4329/wjr.v7.i12.501 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
California Corporate Number: 3537345