BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
6/23/2016 6:00:00 PM | Browse: 1055 | Download: 1927
 |
Received |
|
2015-09-19 14:55 |
 |
Peer-Review Started |
|
2015-09-22 09:17 |
 |
To Make the First Decision |
|
2015-10-27 11:14 |
 |
Return for Revision |
|
2015-10-30 15:34 |
 |
Revised |
|
2015-11-16 15:35 |
 |
Second Decision |
|
2016-03-07 15:49 |
 |
Accepted by Journal Editor-in-Chief |
|
2016-03-07 17:02 |
 |
Accepted by Executive Editor-in-Chief |
|
2016-03-25 14:16 |
 |
Articles in Press |
|
2016-03-25 14:16 |
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
|
 |
Typeset the Manuscript |
|
2016-05-17 15:18 |
 |
Publish the Manuscript Online |
|
2016-06-23 18:00 |
ISSN |
2222-0682 (online) |
Open Access |
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
Copyright |
© The Author(s) 2016. Published by Baishideng Publishing Group Inc. All rights reserved. |
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Chemistry, Medicinal |
Manuscript Type |
Minireviews |
Article Title |
Methods, units and quality requirements for the analysis of haemoglobin A1c in diabetes mellitus
|
Manuscript Source |
Invited Manuscript |
All Author List |
Ilkka Penttilä, Karri Penttilä, Päivi Holm, Harri Laitinen, Päivi Ranta, Jukka Törrönen and Rainer Rauramaa |
Funding Agency and Grant Number |
|
Corresponding Author |
Ilkka Penttilä, MD, PhD, Kuopio Research Institute of Exercise Medicine, University of Eastern Finland, Haapaniementie 16, 70100 Kuopio, Finland. ilkka.penttila@uef.fi |
Key Words |
Diabetes; Hemoglobin A1c; Glycohemoglobin; Glucose; International Federation of Clinical Chemistry and Laboratory Medicine; Reference values; Quality assurance; Recommendation; Target limits |
Core Tip |
The aim of this review is to clarify methods, units, quality requirements, reference and cutoff limits for hemoglobin A1c (HbA1c) and ratio of blood glucose/HbA1c on the basis of the results from Finnish quality control surveys by comparing them to the literature. The HbA1c surveys of Labquality Ltd. (Helsinki, Finland) were started in 1986 by using two fresh EDTA-blood samples. From 1994, the number of the participating laboratories had risen to 139, of which 75 were Finnish and 64 from five other countries. In 2014, the number of the participating laboratories was total 214, 141 were Finnish and 73 from 13 other countries. |
Publish Date |
2016-06-23 18:00 |
Citation |
Penttilä I, Penttilä K, Holm P, Laitinen H, Ranta P, Törrönen J, Rauramaa R. Methods, units and quality requirements for the analysis of haemoglobin A1c in diabetes mellitus. World J Methodol 2016; 6(2): 133-142 |
URL |
http://www.wjgnet.com/2222-0682/full/v6/i2/133.htm |
DOI |
http://dx.doi.org/10.5662/wjm.v6.i2.133 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
California Corporate Number: 3537345