ISSN |
1007-9327 (print) and 2219-2840 (online) |
Open Access |
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
|
Copyright |
© The Author(s) 2016. Published by Baishideng Publishing Group Inc. All rights reserved.
|
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Gastroenterology & Hepatology |
Manuscript Type |
Retrospective Cohort Study |
Article Title |
Contrast-enhanced harmonic endoscopic ultrasonography for assessment of lymph node metastases in pancreatobiliary carcinoma
|
Manuscript Source |
Unsolicited Manuscript |
All Author List |
Takeshi Miyata, Masayuki Kitano, Shunsuke Omoto, Kumpei Kadosaka, Ken Kamata, Hajime Imai, Hiroki Sakamoto, Naoshi Nisida, Yogesh Harwani, Takamichi Murakami, Yoshifumi Takeyama, Yasutaka Chiba and Masatoshi Kudo |
Funding Agency and Grant Number |
Funding Agency |
Grant Number |
Japan Society for the Promotion of Science |
22590764 |
apanese Foundation for the Research and Promotion of Endoscopy |
25461035 |
|
Corresponding Author |
Masayuki Kitano, MD, PhD, Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, 377-2 Ohno-higashi, Osaka-sayama 589-8511,
Japan. m-kitano@med.kindai.ac.jp
|
Key Words |
Contrast-enhanced harmonic endoscopic ultrasonography; Sensitivity and specificity; Lymph node; Pancreatobiliary carcinoma; Endoscopic ultrasonography-fine needle aspiration |
Core Tip |
Diagnosis of malignant intra-abdominal lymph nodes is often challenging for endoscopists and radiologists. In the present study, the diagnostic accuracy for differentiating malignant from benign lymph nodes of standard endoscopic ultrasonography (EUS), color Doppler EUS, and contrast-enhanced harmonic (CH)-EUS relative to EUS-fine needle aspiration (FNA) was assessed. A secondary objective of the present study was to assess the N-stage diagnostic accuracy of CH-EUS and EUS-FNA in patients who underwent surgical resection. In conclusion, CH-EUS was more accurate than standard and color Doppler EUS, except the short axis cut-off. Notably, three patients excluded because of EUS-FNA failure were correctly N-staged by CH-EUS.
|
Publish Date |
2016-03-23 16:22 |
Citation |
Miyata T, Kitano M, Omoto S, Kadosaka K, Kamata K, Imai H, Sakamoto H, Nisida N, Harwani Y, Murakami T, Takeyama Y, Chiba Y, Kudo M. Contrast-enhanced harmonic endoscopic ultrasonography for assessment of lymph node metastases in pancreatobiliary carcinoma. World J Gastroenterol 2016; 22(12): 3381-3391 |
URL |
http://www.wjgnet.com/1007-9327/full/v22/i12/3381.htm |
DOI |
http://dx.doi.org/10.3748/wjg.v22.i12.3381 |