BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
7/24/2016 8:27:00 PM | Browse: 780 | Download: 1346
 |
Received |
|
2016-01-29 10:07 |
 |
Peer-Review Started |
|
2016-02-01 20:03 |
 |
To Make the First Decision |
|
2016-03-23 11:04 |
 |
Return for Revision |
|
2016-03-24 10:03 |
 |
Revised |
|
2016-04-20 00:00 |
 |
Second Decision |
|
2016-04-26 16:25 |
 |
Accepted by Journal Editor-in-Chief |
|
2016-04-26 18:10 |
 |
Accepted by Executive Editor-in-Chief |
|
2016-05-11 15:52 |
 |
Articles in Press |
|
2016-05-11 15:52 |
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
|
 |
Typeset the Manuscript |
|
2016-07-13 13:12 |
 |
Publish the Manuscript Online |
|
2016-07-24 20:27 |
ISSN |
1949-8470 (online) |
Open Access |
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
Copyright |
© The Author(s) 2016. Published by Baishideng Publishing Group Inc. All rights reserved. |
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Radiology, Nuclear Medicine & Medical Imaging |
Manuscript Type |
Retrospective Study |
Article Title |
Value of liver computed tomography with iodixanol 270, 80 kVp and iterative reconstruction
|
Manuscript Source |
Invited Manuscript |
All Author List |
Diomidis Botsikas, Isabelle Barnaure, Sylvain Terraz, Christoph D Becker, Anastasia Kalovidouri and Xavier Montet |
Funding Agency and Grant Number |
|
Corresponding Author |
Diomidis Botsikas, MD, Department of Radiology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, 1205 Geneva, Switzerland. diomidis.botsikas@hcuge.ch
|
Key Words |
Multiphasic dynamic liver computed tomography; Low-kVp computed tomography; Iso-osmolar iodine contrast agent; Low iodine concentration contrast agent; Iterative reconstruction |
Core Tip |
The purpose of this retrospective study was to evaluate the efficiency of hepatic multidetector computed tomography (MDCT) with dynamic contrast enhancement using iodixanol 270 mg/mL and 80 kVp acquisitions reconstructed with sinogram affirmed iterative reconstruction in comparison with a standard protocol using Iohexol 350 mg/mL and 120 kVp acqui-sitions. MDCT imaging with 80 kVp with iterative reconstruction and iodixanol 270 yields equal or even better image quality. The proposed MDCT protocol with less iodine load and lower radiation dose may thus be applied for liver imaging in patients with impaired renal or cardiac function but also in the general population.
|
Publish Date |
2016-07-24 20:27 |
Citation |
Botsikas D, Barnaure I, Terraz S, Becker CD, Kalovidouri A, Montet X. Value of liver computed tomography with iodixanol 270, 80 kVp and iterative reconstruction. World J Radiol 2016; 8(7): 693-699 |
URL |
http://www.wjgnet.com/1949-8470/full/v8/i7/693.htm |
DOI |
http://dx.doi.org/10.4329/wjr.v8.i7.693 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA