BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
9/25/2017 2:01:02 AM | Browse: 1408 | Download: 3010
Publication Name World Journal of Cardiology
Manuscript ID 32526
Country United States
ISSN 1949-8462 (online)
Open Access This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Copyright © The Author(s) 2017. Published by Baishideng Publishing Group Inc. All rights reserved.
Article Reprints For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
Permissions For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
Publisher Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
Website http://www.wjgnet.com
Category Cardiac & Cardiovascular Systems
Manuscript Type Retrospective Study
Article Title Utility and correlation of known anticoagulation parameters in the management of pediatric ventricular assist devices
Manuscript Source Unsolicited Manuscript
All Author List Ajay K Bhatia, Mouhammad Yabrodi, Mallory Carroll, Silvia Bunting, Kirk Kanter, Kevin O Maher and Shriprasad R Deshpande
Funding Agency and Grant Number
Corresponding Author Shriprasad R Deshpande, MD, Division of Pediatric Cardiology, Emory University School of Medicine, Children’s Healthcare of Atlanta, 1405, Clifton Rd NE, Atlanta, GA 30322, United States. deshpandes@kidsheart.com
Key Words Ventricular assist device; Anticoagulation; BERLIN-EXCOR; Pediatric; Thromboelastography
Core Tip This study suggests that while there is strong correlation between activated thromboplastin time, anti-Xa assay and R-thromboelastography values for patients requiring ventricular assist device support, there is a lack of relevant correlation between heparin dose and degree of effect. This raises concern as various guidelines continue to recommend using these parameters to titrate heparin therapy. A comprehensive strategy for appropriate anticoagulation may therefore warrant a combination of parameter monitoring and warrants further study.
Publish Date 2017-09-25 02:01
Citation Bhatia AK, Yabrodi M, Carroll M, Bunting S, Kanter K, Maher KO, Deshpande SR. Utility and correlation of known anticoagulation parameters in the management of pediatric ventricular assist devices. World J Cardiol 2017; 9(9): 749-756
URL http://www.wjgnet.com/1949-8462/full/v9/i9/749.htm
DOI http://dx.doi.org/10.4330/wjc.v9.i9.749
Full Article (PDF) WJC-9-749.pdf
Full Article (Word) WJC-9-749.doc