BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
7/13/2017 11:09:00 AM | Browse: 1411 | Download: 2051
Publication Name World Journal of Clinical Cases
Manuscript ID 33361
Country Italy
ISSN 2307-8960 (online)
Open Access This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Copyright © The Author(s) 2017. Published by Baishideng Publishing Group Inc. All rights reserved.
Article Reprints For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
Permissions For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
Publisher Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
Website http://www.wjgnet.com
Category Medicine, Research & Experimental
Manuscript Type Minireviews
Article Title New device to implement the adenoma detection rate
Manuscript Source Invited Manuscript
All Author List Maddalena Zippi, Wandong Hong, Pietro Crispino and Giampiero Traversa
Funding Agency and Grant Number
Corresponding Author Maddalena Zippi, MD, PhD, Unit of Gastroenterology and Digestive Endoscopy, Sandro Pertini Hospital, Via dei Monti Tiburtini 385, 00157 Rome, Italy. maddalena.zippi@aslroma2.it
Key Words Adenoma detection rate; Cap-assisted colonoscopy; Colorectal cancer; Endocuff-assisted colono­scopy; Standard colonoscopies
Core Tip One of the main goals of colonoscopy screening is to identify polypoid lesions, which are precursors of colorectal cancer. Once identified, the polypoid lesions need to be removed whenever possible. Throughout the years, many prototypes of colonoscopes, magnification techniques, and different devices such as caps have been developed for colonoscopy screening. Endocuff is a new device used to improve adenoma detection rates during colonoscopy. Based on the findings of many studies, Endocuff seems to be of great help in increasing the detection of colonic polyps, with no significant complications associated with its use.
Publish Date 2017-07-13 11:09
Citation Zippi M, Hong W, Crispino P, Traversa G. New device to imple­ment the adenoma detection rate. World J Clin Cases 2017; 5(7): 258-263
URL http://www.wjgnet.com-/2307-8960/full/v5/i7/258.htm
DOI http://dx.doi.org/10.12998/wjcc.v5.i7.258
Full Article (PDF) WJCC-5-258.pdf