BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
9/12/2014 8:40:00 PM | Browse: 989 | Download: 774
Publication Name World Journal of Gastroenterology
Manuscript ID 4218
Country China
Received
2013-06-21 09:03
Peer-Review Started
2013-06-21 15:28
To Make the First Decision
2013-07-05 18:22
Return for Revision
2013-07-15 22:42
Revised
2013-07-24 17:55
Second Decision
2013-08-20 12:12
Accepted by Journal Editor-in-Chief
Accepted by Company Editor-in-Chief
2013-08-20 13:46
Articles in Press
Publication Fee Transferred
Edit the Manuscript by Language Editor
2013-09-04 01:12
Typeset the Manuscript
2013-10-08 18:51
Publish the Manuscript Online
2013-10-15 17:26
ISSN 1007-9327 (print) and 2219-2840 (online)
Open Access
Copyright
Article Reprints For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
Permissions For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
Publisher Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
Website http://www.wjgnet.com
Category Gastroenterology & Hepatology
Manuscript Type Case Report
Article Title Plastic tube-assisted gastroscopic removal of embedded esophageal metal stents: A case report
Manuscript Source Invited Manuscript
All Author List Gui-Yong Peng, Xiu-Feng Kang, Xin Lu, Lei Chen and Qian Zhou
Funding Agency and Grant Number
Funding Agency Grant Number
National Natural Science Foundation 81070384
Corresponding Author Gui-Yong Peng, MD, Professor, Department of Gastroenterology of Southwest Hospital, The Third Military Medical University, NO. 1 Gaotanyan Street, Shapingba District, Chongqing 400038, China. pgy63@163.com
Key Words Esophagus; Stents; Gastroscope; Complication
Core Tip A patient presented with a disordered stent structure as a result of failure of repeated attempts at gastroscopic removal. An ST-E tube was inserted into the esophagus. An alligator forceps was inserted into the ST-E tube alongside a gastroscope. The stent wire was gripped and pulled up into the tube. Biopsy forceps were inserted into the lower section of the stent through the biopsy hole to fix the stent, while the alligator forceps continued to be used to pull up the stent wire until the Z-shaped metal loops became elongated stripes. All the stent wire was removed through the ST-E tube.
Publish Date 2013-10-15 17:26
Citation Peng GY, Kang XF, Lu X, Chen L, Zhou Q. Plastic tube-assisted gastroscopic removal of embedded esophageal metal stents: A case report. World J Gastroenterol 2013; 19(38): 6505-6508
URL http://www.wjgnet.com/1007-9327/full/v19/i38/6505.htm
DOI http://dx.doi.org/10.3748/wjg.v19.i38.6505
Full Article (PDF) WJG-19-6505.pdf
Manuscript File 4218-Review.doc
Answering Reviewers 4218-Answering reviewers.doc
Copyright License Agreement 4218-Copyright assignment.pdf
Non-Native Speakers of English Editing Certificate Letter .doc
Peer-review Report 4218-Peer review(s).pdf
Scientific Editor Work List 4218-Scientific editor work list.doc