BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
4/13/2019 6:00:06 AM | Browse: 1065 | Download: 2089
Publication Name World Journal of Gastroenterology
Manuscript ID 46305
Country China
ISSN 1007-9327 (print) and 2219-2840 (online)
Open Access This article is an open-access article which was selected byan in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Copyright © The Author(s) 2019. Published by Baishideng Publishing Group Inc. All rights reserved.
Article Reprints For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
Permissions For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
Publisher Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
Website http://www.wjgnet.com
Category Gastroenterology & Hepatology
Manuscript Type Case Report
Article Title Application of a 3D-printed ”fistula stent” in plugging enteroatmospheric fistula with open abdomen: A case report
Manuscript Source Unsolicited Manuscript
All Author List Zi-Yan Xu, Hua-Jian Ren, Jin-Jian Huang, Zong-An Li and Jian-An Ren
ORCID
Author(s) ORCID Number
Zi-Yan Xu http://orcid.org/0000-0001-9027-1282
Hua-Jian Ren http://orcid.org/0000-0002-2205-4072
Jin-Jian Huang http://orcid.org/0000-0002-8951-8935
Zong-An Li http://orcid.org/0000-0002-3580-5891
Jian-An Ren http://orcid.org/0000-0002-4697-4762
Funding Agency and Grant Number
Corresponding Author Jian-An Ren, FACS, MD, PhD, Chief Doctor, Professor, Surgeon, Research Institute of General Surgery, Jinling Hospital, 305 East Zhongshan Road, Nanjing 210002, Jiangsu Province, China. jiananr@gmail.com
Key Words 3D printing; Enteroatmospheric fistula; Open abdomen; Isolation technique; Case report
Core Tip Few methods can be utilized to control enteroatomospheric fistulas (EAFs) which are unlikely to achieve spontaneous closure. The 3D-printed “fistula stent” presented here can be implanted to close EAF in the early stage of open abdomen. We think this report could start the train of thought for plugging EAF to reduce the lost enteric effluent as well as avoid water electrolyte imbalance, corrosion on the wound surface and intra-abdominal infection.
Publish Date 2019-04-13 06:00
Citation Xu ZY, Ren HJ, Huang JJ, Li ZA, Ren JA. Application of a 3D-printed ”fistula stent” in plugging enteroatmospheric fistula with open abdomen: A case report. World J Gastroenterol 2019; 25(14): 1775-1782
URL https://www.wjgnet.com/1007-9327/full/v25/i14/1775.htm
DOI https://dx.doi.org/10.3748/wjg.v25.i14.1775
Full Article (PDF) WJG-25-1775.pdf
Full Article (Word) WJG-25-1775.docx