BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
8/6/2020 9:52:05 AM | Browse: 434 | Download: 815
 |
Received |
|
2020-04-09 09:47 |
 |
Peer-Review Started |
|
2020-04-09 09:47 |
 |
To Make the First Decision |
|
|
 |
Return for Revision |
|
2020-04-29 00:45 |
 |
Revised |
|
2020-05-11 11:32 |
 |
Second Decision |
|
2020-07-13 10:14 |
 |
Accepted by Journal Editor-in-Chief |
|
|
 |
Accepted by Executive Editor-in-Chief |
|
2020-07-14 22:11 |
 |
Articles in Press |
|
2020-07-14 22:11 |
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
2020-07-20 00:14 |
 |
Typeset the Manuscript |
|
2020-08-04 09:30 |
 |
Publish the Manuscript Online |
|
2020-08-06 09:52 |
ISSN |
2307-8960 (online) |
Open Access |
This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
Copyright |
© The Author(s) 2020. Published by Baishideng Publishing Group Inc. All rights reserved. |
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Ophthalmology |
Manuscript Type |
Clinical Trials Study |
Article Title |
Comparison measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
|
Manuscript Source |
Unsolicited Manuscript |
All Author List |
Zi-Yan Yu, Ting Huang, Lu Lu and Bo Qu |
ORCID |
|
Funding Agency and Grant Number |
|
Corresponding Author |
Bo Qu, MD, PhD, Associate Professor, Department of Ophthalmology, 4th Affiliated Hospital of China Medical University, Eye Hospital of China Medical University, Key Laboratory of Lens Research of Liaoning Province, No. 11, Xinhua Road, Shenyang 110004, Liaoning Province, China. dolphinemu@foxmail.com |
Key Words |
Anterior segment-optical coherence tomography; Primary angle closure glaucoma; Anterior chamber angle; Angel opening distance at 500 m; Trabeculo-iris space area at 500 m2; |
Core Tip |
Aucoma is an irreversible optic neuropathy with the loss of visual field and decrease of vision. The early screening and diagnosis of glaucoma are currently experiencing a demand in anterior segment analysis tools that can gather more information with one short measurement. In this study, we compared the agreement, difference and correlation of anterior chamber angle parameters such as angel opening distance at 500 μm and trabeculo-iris space area at 500 μm2 measured anterior segment optical coherence tomography and ultrasound biomicroscopy. |
Publish Date |
2020-08-06 09:52 |
Citation |
Yu ZY, Huang T, Lu L, Qu B. Comparison measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy. World J Clin Cases 2020; 8(15): 3249-3258 |
URL |
https://www.wjgnet.com/2307-8960/full/v8/i15/3249.htm |
DOI |
https://dx.doi.org/10.12998/wjcc.v8.i15.3249 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
California Corporate Number: 3537345