BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
5/13/2022 8:46:13 AM | Browse: 263 | Download: 706
 |
Received |
|
2021-10-15 10:31 |
 |
Peer-Review Started |
|
2021-10-15 10:32 |
 |
To Make the First Decision |
|
|
 |
Return for Revision |
|
2022-01-11 07:15 |
 |
Revised |
|
2022-01-20 05:44 |
 |
Second Decision |
|
2022-03-18 06:12 |
 |
Accepted by Journal Editor-in-Chief |
|
|
 |
Accepted by Executive Editor-in-Chief |
|
2022-03-26 21:49 |
 |
Articles in Press |
|
2022-03-26 21:49 |
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
2022-03-12 23:23 |
 |
Typeset the Manuscript |
|
2022-04-19 06:40 |
 |
Publish the Manuscript Online |
|
2022-05-13 08:46 |
ISSN |
2307-8960 (online) |
Open Access |
This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: https://creativecommons.org/Licenses/by-nc/4.0/ |
Copyright |
©The Author(s) 2022. Published by Baishideng Publishing Group Inc. All rights reserved. |
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Anesthesiology |
Manuscript Type |
Case Report |
Article Title |
Perianesthesia emergency repair of a cut endotracheal tube’s inflatable tube: A case report
|
Manuscript Source |
Unsolicited Manuscript |
All Author List |
Ting-Ting Wang, Jiang Wang, Ting-Ting Sun, Yu-Ting Hou, Yao Lu and Shan-Gui Chen |
ORCID |
|
Funding Agency and Grant Number |
|
Corresponding Author |
Shan-Gui Chen, MNurs, Chief Nurse, Department of Anesthesiology, The First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Hefei 230000, Anhui Province, China. chenshanguimz@163.com |
Key Words |
Perianesthesia accident; Emergency situation; Endotracheal tube; Inflatable tube; Tonsillectomy; Mechanical ventilation; Case report |
Core Tip |
We report a case of perianesthesia in which the trachea tube’s inflatable tube was damaged due to a surgical error, causing a ventilation disorder and triggering the anesthesia machine alarm suggesting low tidal volume. In case of an emergency, our team uses an intravenous catheter to quickly and effectively patch the inflatable tube temporarily to ensure smooth operation and patient safety. |
Publish Date |
2022-05-13 08:46 |
Citation |
Wang TT, Wang J, Sun TT, Hou YT, Lu Y, Chen SG. Perianesthesia emergency repair of a cut endotracheal tube’s inflatable tube: A case report. World J Clin Cases 2022; 10(14): 4594-4600 |
URL |
https://www.wjgnet.com/2307-8960/full/v10/i14/4594.htm |
DOI |
https://dx.doi.org/10.12998/wjcc.v10.i14.4594 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
California Corporate Number: 3537345