BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
3/22/2024 11:13:53 AM | Browse: 243 | Download: 893
 |
Received |
|
2023-10-07 16:03 |
 |
Peer-Review Started |
|
2023-10-07 16:04 |
 |
First Decision by Editorial Office Director |
|
2023-12-08 17:30 |
 |
Return for Revision |
|
2023-12-11 03:58 |
 |
Revised |
|
2024-01-07 05:53 |
 |
Publication Fee Transferred |
|
|
 |
Second Decision by Editor |
|
2024-02-18 07:08 |
 |
Second Decision by Editor-in-Chief |
|
|
 |
Final Decision by Editorial Office Director |
|
2024-02-18 07:41 |
 |
Articles in Press |
|
2024-02-18 07:41 |
 |
Edit the Manuscript by Language Editor |
|
2024-02-14 23:04 |
 |
Typeset the Manuscript |
|
2024-03-09 14:46 |
 |
Publish the Manuscript Online |
|
2024-03-22 11:13 |
| ISSN |
1948-9366 (online) |
| Open Access |
This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/Licenses/by-nc/4.0/ |
| Copyright |
© The Author(s) 2024. Published by Baishideng Publishing Group Inc. All rights reserved. |
| Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
| Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
| Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
| Website |
http://www.wjgnet.com |
| Category |
Gastroenterology & Hepatology |
| Manuscript Type |
Meta-Analysis |
| Article Title |
Endoscopic-ultrasound-guided biliary drainage with placement of electrocautery-enhanced lumen-apposing metal stent for palliation of malignant biliary obstruction: Updated meta-analysis
|
| Manuscript Source |
Unsolicited Manuscript |
| All Author List |
Zu-Xiang Peng, Fang-Fang Chen, Wen Tang, Xu Zeng, Hong-Juan Du, Ru-Xian Pi, Hong-Ming Liu and Xiao-Xiao Lu |
| ORCID |
|
| Funding Agency and Grant Number |
|
| Corresponding Author |
Hong-Ming Liu, PhD, Director, Director, Doctor, Doctor, Department of Hepatobiliary Surgery, Daping Hospital, Army Medical University, Chongqing 400042, China. liuhongming74@163.com |
| Key Words |
Biliary obstruction; Biliary drainage; Electrocautery-enhanced lumen-apposing metal stents; Endoscopic ultrasound; Endoscopic retrograde cholangiopancreatography failure |
| Core Tip |
Electrocautery-enhanced lumen-apposing metal stent (ECE-LAMS) has been developed to perform biliary drainage. Because small, heterogeneous observational studies might be underpowered to identify the efficacy and safety of endoscopic ultrasound (EUS)-guided biliary drainage with ECE-LAMS, a comprehensive study is required. Therefore, we did a meta-analysis and systematic review to evaluate the efficacy and safety of EUS-guided biliary drainage with ECE-LAMS. |
| Publish Date |
2024-03-22 11:13 |
| Citation |
Peng ZX, Chen FF, Tang W, Zeng X, Du HJ, Pi RX, Liu HM, Lu XX. Endoscopic-ultrasound-guided biliary drainage with placement of electrocautery-enhanced lumen-apposing metal stent for palliation of malignant biliary obstruction: Updated meta-analysis. World J Gastrointest Surg 2024; 16(3): 907-920 |
| URL |
https://www.wjgnet.com/1948-9366/full/v16/i3/907.htm |
| DOI |
https://dx.doi.org/10.4240/wjgs.v16.i3.907 |
All content on this site: Copyright © 1993-2026 Baishideng Publishing Group Inc, its licensors, and contributors. All rights are reserved, including those for text and data mining, AI training, and similar technologies. For all open access content, the relevant licensing terms apply.