BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
4/16/2024 7:57:41 AM | Browse: 71 | Download: 296
 |
Received |
|
2023-11-14 15:56 |
 |
Peer-Review Started |
|
2023-11-14 15:57 |
 |
To Make the First Decision |
|
|
 |
Return for Revision |
|
2024-01-24 06:22 |
 |
Revised |
|
2024-02-05 14:31 |
 |
Second Decision |
|
2024-03-27 02:36 |
 |
Accepted by Journal Editor-in-Chief |
|
|
 |
Accepted by Executive Editor-in-Chief |
|
2024-03-27 05:34 |
 |
Articles in Press |
|
2024-03-27 05:34 |
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
|
 |
Typeset the Manuscript |
|
2024-04-10 01:27 |
 |
Publish the Manuscript Online |
|
2024-04-16 07:57 |
ISSN |
2307-8960 (online) |
Open Access |
This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: https://creativecommons.org/Licenses/by-nc/4.0/ |
Copyright |
The Author(s) 2024. Published by Baishideng Publishing Group Inc. All rights reserved. |
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Surgery |
Manuscript Type |
Case Report |
Article Title |
Basilic vein variation encountered during surgery for arm vein port: A case report
|
Manuscript Source |
Unsolicited Manuscript |
All Author List |
Cheng-Da Hu, Rui Lv, Ya-Xin Zhao, Ming-Hao Zhang, Hong-Dou Zeng and Yi-Wen Mao |
ORCID |
|
Funding Agency and Grant Number |
|
Corresponding Author |
Ya-Xin Zhao, MD, Chief Physician, Department of Breast Surgery, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, No. 1111 Wenzhou Avenue, Wenzhou 325000, Zhejiang Province, China. zyx@wmu.edu.cn |
Key Words |
Totally implantable venous access ports; Arm ports; Venous variation; Postoperative breast cancer; Systematic review; Case report |
Core Tip |
Venous variation refers to structural malformations caused by abnormal development of venous vessels. At present, the etiology is still unknown. In the process of implanting the arm port for a tumor postoperative patient, we found and reported a case of successful treatment of basilic vein variation encountered during the operation, which can provide a reference for such cases in the future. |
Publish Date |
2024-04-16 07:57 |
Citation |
Hu CD, Lv R, Zhao YX, Zhang MH, Zeng HD, Mao YW. Basilic vein variation encountered during surgery for arm vein port: A case report. World J Clin Cases 2024; 12(12): 2086-2091 |
URL |
https://www.wjgnet.com/2307-8960/full/v12/i12/2086.htm |
DOI |
https://dx.doi.org/10.12998/wjcc.v12.i12.2086 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
California Corporate Number: 3537345