BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
2/12/2025 2:27:43 AM | Browse: 169 | Download: 705
Publication Name World Journal of Orthopedics
Manuscript ID 98674
Country Poland
ISSN 2218-5836 (online)
Open Access This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: https://creativecommons.org/Licenses/by-nc/4.0/
Copyright © The Author(s) 2025. Published by Baishideng Publishing Group Inc. All rights reserved.
Article Reprints For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
Permissions For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
Publisher Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
Website http://www.wjgnet.com
Category Orthopedics
Manuscript Type Case Report
Article Title Periprosthetic fractures of the tibial shaft following long-stemmed total knee arthroplasty: A case report
Manuscript Source Unsolicited Manuscript
All Author List Maciej Kocon and Dariusz Grzelecki
ORCID
Author(s) ORCID Number
Dariusz Grzelecki http://orcid.org/0000-0003-1812-7061
Funding Agency and Grant Number
Corresponding Author Dariusz Grzelecki, Associate Professor, MD, PhD, Department of Orthopedics and Rheumoorthopedics, Centre of Postgraduate Medical Education, Konarskiego 13, Otwock 05-400, Mazowieckie, Poland. dariuszgrzelecki@gmail.com
Key Words Periprosthetic fracture; Tibia fracture; Pseudarthrosis; Revision total knee arthroplasty; Intramedullary stabilization; Case report
Core Tip Periprosthetic tibial fractures after long-stemmed total knee arthroplasties require planning and a personalized approach for each case. We recommend planning intramedullary fixation with long-stemmed implants or revision total knee arthroplasty with intramedullary nailing for fractures localized on the tibial shaft.
Publish Date 2025-02-12 02:27
Citation

Kocon M, Grzelecki D. Periprosthetic fractures of the tibial shaft following long-stemmed total knee arthroplasty: A case report. World J Orthop 2025; 16(2): 98674

URL https://www.wjgnet.com/2218-5836/full/v16/i2/98674.htm
DOI https://dx.doi.org/10.5312/wjo.v16.i2.98674
Full Article (PDF) WJO-16-98674-with-cover.pdf