BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
10/26/2016 3:44:00 PM | Browse: 947 | Download: 2141
 |
Received |
|
2016-05-08 12:10 |
 |
Peer-Review Started |
|
2016-05-09 01:21 |
 |
First Decision by Editorial Office Director |
|
|
 |
Return for Revision |
|
2016-06-13 16:46 |
 |
Revised |
|
2016-07-10 19:48 |
 |
Publication Fee Transferred |
|
|
 |
Second Decision by Editor |
|
2016-08-22 13:53 |
 |
Second Decision by Editor-in-Chief |
|
|
 |
Final Decision by Editorial Office Director |
|
2016-08-31 12:18 |
 |
Articles in Press |
|
2016-08-31 12:18 |
 |
Edit the Manuscript by Language Editor |
|
|
 |
Typeset the Manuscript |
|
2016-10-25 13:10 |
 |
Publish the Manuscript Online |
|
2016-10-26 15:44 |
| ISSN |
1949-8462 (online) |
| Open Access |
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
| Copyright |
© The Author(s) 2016. Published by Baishideng Publishing Group Inc. All rights reserved. |
| Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
| Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
| Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
| Website |
http://www.wjgnet.com |
| Category |
Medicine, Research & Experimental |
| Manuscript Type |
Clinical Trials Study |
| Article Title |
Optimal C-arm angulation during transcatheter aortic valve replacement: Accuracy of a rotational C-arm computed tomography based three dimensional heart model
|
| Manuscript Source |
Unsolicited Manuscript |
| All Author List |
Verena Veulemans, Sabine Mollus, Axel Saalbach, Max Pietsch, Katharina Hellhammer, Tobias Zeus, Ralf Westenfeld, Jürgen Weese, Malte Kelm and Jan Balzer |
| Funding Agency and Grant Number |
|
| Corresponding Author |
Verena Veulemans, MD, Department of Medicine, Division of Cardiology, Pulmonary Diseases, Vascular Medicine, University Hospital Düsseldorf, Moorenstraße 5, 40225 Düsseldorf,
Germany. verena.veulemanns@med.uni-duesseldorf.de
|
| Key Words |
Aortic stenosis; Imaging modalities; Degenerative valve disease; Transcatheter aortic valve replacement |
| Core Tip |
We were able to demonstrate the accuracy of a rotational C-arm CT (RCT) based 3D heart model to predict an optimal C-arm configuration and to provide anatomical context information during transcatheter aortic valve replacement (TAVR). Established and up-coming complex cardiac interventions require detailed anatomical information for procedure planning and intra-procedural guidance. According to our experience, RCT can be smoothly integrated into the clinical workflow, providing three-dimensional information of the relevant anatomical structures in the catheterization lab prior and as part of the TAVR intervention.
|
| Publish Date |
2016-10-26 15:44 |
| Citation |
Veulemans V, Mollus S, Saalbach A, Pietsch M, Hellhammer K, Zeus T, Westenfeld R, Weese J, Kelm M, Balzer J. Optimal C-arm angulation during transcatheter aortic valve replacement: Accuracy of a rotational C-arm computed tomography based three dimensional heart model. World J Cardiol 2016; 8(10): 606-614 |
| URL |
http://www.wjgnet.com/1949-8462/full/v8/i10/606.htm |
| DOI |
http://dx.doi.org/10.4330/wjc.v8.i10.606 |
All content on this site: Copyright © 1993-2026 Baishideng Publishing Group Inc, its licensors, and contributors. All rights are reserved, including those for text and data mining, AI training, and similar technologies. For all open access content, the relevant licensing terms apply.