4/18/2019 10:30:43 AM | Browse: 1007 | Download: 1472
 |
Received |
|
2019-01-02 06:42 |
 |
Peer-Review Started |
|
2019-01-04 05:19 |
 |
First Decision by Editorial Office Director |
|
2019-01-26 18:01 |
 |
Return for Revision |
|
2019-02-14 02:05 |
 |
Revised |
|
2019-02-18 01:37 |
 |
Publication Fee Transferred |
|
|
 |
Second Decision by Editor |
|
2019-03-15 08:13 |
 |
Second Decision by Editor-in-Chief |
|
|
 |
Final Decision by Editorial Office Director |
|
2019-03-16 15:51 |
 |
Articles in Press |
|
2019-03-16 15:51 |
 |
Edit the Manuscript by Language Editor |
|
2019-03-25 02:58 |
 |
Typeset the Manuscript |
|
2019-04-18 02:17 |
 |
Publish the Manuscript Online |
|
2019-04-18 10:30 |
| ISSN |
2218-5836 (online) |
| Open Access |
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
| Copyright |
© The Author(s) 2019. Published by Baishideng Publishing Group Inc. All rights reserved. |
| Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
| Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
| Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
| Website |
http://www.wjgnet.com |
| Category |
Orthopedics |
| Manuscript Type |
Case Report |
| Article Title |
Fracture of allograft interbody spacer resulting in post-operative radiculopathy: A case report
|
| Manuscript Source |
Unsolicited Manuscript |
| All Author List |
Andrews Kyle, Andrea Rowland, Jacob Stirton and Hossein Elgafy |
| ORCID |
|
| Funding Agency and Grant Number |
|
| Corresponding Author |
Hossein Elgafy, FRCS (Ed), FRSC, MD, Professor, Surgeon, Department of Orthopedics, University of Toledo Medical Centre, 3065 Arlington Avenue, Toledo, OH 43614-5807, United States. hossein.elgafy@utoledo.edu |
| Key Words |
Transforaminal lumbar interbody fusion; Interbody fusion; Allograft interbody spacer; Postoperative radiculopathy; Graft breakage; Case report |
| Core Tip |
Allograft interbody spacers are commonly used in lumbar transforaminal lumbar interbody fusion procedures. A complication previously undocumented in the literature, we report on a fractured allograft interbody spacer that displaced into the neural foramen and resulted in impingement on the exiting nerve root that required revision. At 12 mo post-op, the patient was doing well with computed tomography -scan confirming fusion and subsequent removal of the impinging fractured graft fragment. While presumably a rare occurrence, the authors review several technical points to avoid this complication. |
| Publish Date |
2019-04-18 10:30 |
| Citation |
Kyle A, Rowland A, Stirton J, Elgafy H. Fracture of allograft interbody spacer resulting in post-operative radiculopathy: A case report. World J Orthop 2019; 10(4): 206-211 |
| URL |
https://www.wjgnet.com/2218-5836/full/v10/i4/206.htm |
| DOI |
https://dx.doi.org/10.5312/wjo.v10.i4.206 |