BPG is committed to discovery and dissemination of knowledge
Articles Published Processes
11/13/2020 6:52:32 AM | Browse: 381 | Download: 1292
 |
Received |
|
2020-08-12 10:36 |
 |
Peer-Review Started |
|
2020-08-12 10:36 |
 |
To Make the First Decision |
|
|
 |
Return for Revision |
|
2020-08-22 04:34 |
 |
Revised |
|
2020-08-29 09:37 |
 |
Second Decision |
|
2020-09-09 11:30 |
 |
Accepted by Journal Editor-in-Chief |
|
|
 |
Accepted by Executive Editor-in-Chief |
|
2020-09-09 22:41 |
 |
Articles in Press |
|
2020-09-09 22:41 |
 |
Publication Fee Transferred |
|
|
 |
Edit the Manuscript by Language Editor |
|
2020-09-23 23:55 |
 |
Typeset the Manuscript |
|
2020-11-04 01:15 |
 |
Publish the Manuscript Online |
|
2020-11-13 06:52 |
ISSN |
1007-9327 (print) and 2219-2840 (online) |
Open Access |
This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/Licenses/by-nc/4.0/ |
Copyright |
© The Author(s) 2020. Published by Baishideng Publishing Group Inc. All rights reserved. |
Article Reprints |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/247
|
Permissions |
For details, please visit: http://www.wjgnet.com/bpg/gerinfo/207
|
Publisher |
Baishideng Publishing Group Inc, 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA |
Website |
http://www.wjgnet.com |
Category |
Gastroenterology & Hepatology |
Manuscript Type |
Basic Study |
Article Title |
Fedora-type magnetic compression anastomosis device for intestinal anastomosis
|
Manuscript Source |
Unsolicited Manuscript |
All Author List |
Huan Chen, Tao Ma, Yue Wang, Hao-Yang Zhu, Zhe Feng, Rong-Qian Wu, Yi Lv and Ding-Hui Dong |
ORCID |
|
Funding Agency and Grant Number |
Funding Agency |
Grant Number |
National Natural Science Foundation of China (to Lv Y) |
81470896 |
|
Corresponding Author |
Ding-Hui Dong, MD, PhD, Surgeon, Teacher, National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, No. 76 West Yanta Road, Xi’an 710061, Shaanxi Province, China. dongdinghui0510@163.com |
Key Words |
Magnetic compression anastomosis; Anastomotic stenosis; Size of anastomat; Compression pressure; Fedora-type magnetic compression anastomosis device; |
Core Tip |
To address some of the deficiencies in the current magnetic compression anastomosis (MCA) model, we explored the optimal size and pressure of the MCA device for intestinal anastomosis in rats. We found that the suggested diameter of the MCA device should be larger than 120% of the enteric diameter to avoid stenosis. Further, we developed a novel “fedora-type” MCA device for the current model, using a Φ4-mm nummular magnet with a Φ6-mm sheet metal. This model safely formed anastomosis and ensured long-term anastomosis. This novel anastomat controlled pressure and optimized the size, thus meeting our stipulated requirements. |
Publish Date |
2020-11-13 06:52 |
Citation |
Chen H, Ma T, Wang Y, Zhu HY, Feng Z, Wu RQ, Lv Y, Dong DH. Fedora-type magnetic compression anastomosis device for intestinal anastomosis. World J Gastroenterol 2020; 26(42): 6614-6625 |
URL |
https://www.wjgnet.com/1007-9327/full/v26/i42/6614.htm |
DOI |
https://dx.doi.org/10.3748/wjg.v26.i42.6614 |
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA
California Corporate Number: 3537345